O'D-Air G248 Dual - Air Ioniser & Ozone Generator with Water Function

O'D-Air G248 Dual - Air Ioniser & Ozone Generator with Water Function

SKU: 90519
£139.95

(Out of Stock)
O'D-Air G248 Dual - Air Ioniser & Ozone Generator with Water Function

O'D-Air G248 Dual - Air Ioniser & Ozone Generator with Water Function

The brilliant new O'd-air Dual-function Air Ioniser and Ozone Generator utilises not one but 2 of the most effective air cleaning methods to erradicate smells and air-borne microbes. Firstly, an air ioniser helps remove airborne particles such as dust, pollen and bacteria. Secondly, an ozone generator produces O3 which kills bacteria, viruses and mould spores. The unit comes with airline and air stones so that the ozone can be bubbled into water in your reservoir, killing pathogens and making it safe for your plants.

Both the ioniser and the ozone generator have seperate timers so that the amount of each put out by the unit is controllable. This unit is perfect for helping to reduce smells and keeping the bad microbes at bay. Brilliant!

Read our Blog about Ozone Here

  • O'D-air G248 - Great all round odour and disease control
  • Perfect for use inside a grow-room
  • Drastically reduces odours
  • Inhibits mould and bacterial infections
  • Separate timers for the air ioniser (plasma) and ozone generator give you great controllability
  • Produces up to 400mg/hr of ozone
  • Ozone can be bubbled through reservoir or feed water to kill diseases
  • Ozone generator can be set to run continously 30 minutes on - 5 minutes off, or set for a one-off period of 5-30 minutes, or set to OFF.
  • Air Ioniser (Plasma) can be set to run from 30 minutes to 8 hours (in 30 minute increments), or set to OFF. (There is no continuous Plasma mode)

The O'D-Air G248 Dual - Air Ioniser & Ozone Generator with Water Function Contains:

1 x O'D-Air Dual - Air Ioniser & Ozone Generator with Water Function, 1 x Air Stone, 1 length of Airline tubing

How the O'D-Air G2480 Dual - Air Ioniser & Ozone Generator with Water Function works:

The O'D-Air G248 Dual function air ioniser and ozone generator has been designed especially for hydroponics growers who need additional odour and disease control in their grow-room. First of all, the unit produces ionised air which precipitates dust, pollen and odour particles out of the air while inhibiting bacteria and other air-borne microbes. Secondly the O'D-Air produces Ozone which is even more effective at sterilisation. Ozone will kill the microbes (bacteria, molds) which create smells, and also kills viruses and the spores released by molds which could infect your plants.

Alternatively the ozone can be bubbled through the supplied air line tubing and air stone and into your reservoir or feed water. This will effectiveliy sterilise the water, making it much safer for your plants.

Each generator has a separate timer so that you can control the ozone output and the plasma (air ionisation) outputs individually.

The ozone generator can be set to run on a continuous cycle of 30 minutes on followed by 5 minutes off, or set to run for a one-off period of 5 to 30 minutes (in 5 minute increments) or switched completely OFF.

The air ioniser can be set to run for a one-off period of 30 minutes to 8 hours (in 30 minute increments), or set to OFF. There is no continuous mode for the Plasma generator

Using the O'D-Air G248 Dual - Air Ioniser & Ozone Generator with Water Function

Ozone is heavier than air and for this reason the O'D-Air G248 should be placed on a shelf or mounted in a location which is as high up as possible within the room in which it is to be used if the Ozone output is to be used to clean air and not water. If the ozone is to be used to sterilise your reservoir / feed water then the unit should be located conveniently close to your reservoir or feed water container.

Ensure that the 5 holes on the front of the unit, which release ionised air, are not restricted, and that air can flow into and out of the unit freely. The ozone flows out of the side connector. This should be left clear if the ozone is being used to clean and sanitise air. If the ozone output is being used to sanitise water then attach a length of the supplied air line tubing onto the connector onto the side of the unit. Attach one of the air stones onto the other end of the air line and lower it into your reservoir or feed water container.

Plug the O'D-Air G248 into a convenient mains socket and switch on.

 

Controlling the Ozone Output:

Pressing the "Ozone" button cycles the timer through "Continuous mode", "One-off treatment mode" and OFF. Pressing the Ozone button again will take it back to the beginning of the menu (i.e. Continuous mode).

In Continuous mode, the display will initially show C:30 (the “C” indicates that the ozone generator is in "Continuous" mode). In this mode, the Ozone generator will operate for 30 minutes and then switch off for 5 minutes. It will continue this cycle of 30mins on/5mins off until the unit is switched off by the user. The on and off time-length cannot be adjusted.

In "One-off treatment" mode, the display begins on 0:05 indicating 5 minutes. Use the + and - buttons to adjust by 5 minute increments the amount of minutes that you want the unit to produce ozone for (up to a maximum of 30 minutes). In this non-continuous mode, as soon as the set period has ended, the unit will stop producing ozone until the user switches it on again.

Pressing the ozone button again switches the ozone generator off. This takes a couple of seconds because the unit finishes pumping out the Ozone that it has already made.

 

Controlling the Air Ioniser (Plasma) Output:

For the Air ioniser (Plasma) output, press the button marked Plasma. The display will initially show 2:00 indicating that the air ioniser will operate for 2 hours and then switch off. Use the + and - buttons to adjust the length of time you want the unit to produce plasma for. This can be adjusted from 30 minutes to 8 hours in 30 minute increments. Once the set time-period has passed, the unit will stop producing Plasma until the user switches it back on again. To switch the air ioniser off at any point when it is on, press the Plasma button until the Plasma light goes out. There is no continuous mode for the Plasma output.

Warnings:

Do not inhale the air from around the generator (or the air leaving the air stone) as this can be very rich in ozone and therefore could be a hazard to health. It is a very wise precaution to switch the O'D-Air G248 off for 30 minutes to an hour before you start working in your grow-room to allow the ozone to dissipate and be extracted. People (particularly children) and animals should be kept out of any area which may contain elevated levels of ozone.

The O'D-Air G248 is incredibly effective at reducing odours. However, it is NOT a replacement for a filter and extraction fan which should still be used to remove stale air from your grow-room.