{"product_id":"aqua-master-substrate-ec-temp-e300-pro","title":"Aqua Master Substrate EC\/Temp E300 Pro","description":"\u003ch2\u003eMeasure EC Directly in the Root Zone\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eAqua Master Substrate EC\/Temp E300 Pro\u003c\/strong\u003e lets you measure \u003cstrong\u003eEC and temperature directly in moist growing media\u003c\/strong\u003e such as coco, soil and other soft substrates, as well as in nutrient solutions and other liquids.\u003c\/p\u003e\n\n\u003cp\u003eRather than relying only on the EC of the feed going into your plants, the E300 Pro lets you check what is actually happening around the roots. That makes it particularly useful for spotting nutrient build-up, monitoring root-zone strength and diagnosing feeding problems before they become more serious.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect substrate EC testing:\u003c\/strong\u003e measure nutrient strength directly in moist coco, soil and other soft growing media;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasures temperature too:\u003c\/strong\u003e check root-zone temperature at the same time as EC;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWorks in liquids:\u003c\/strong\u003e can also be used to test nutrient solutions and reservoirs;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide EC range:\u003c\/strong\u003e measures from 0.0 to 19.9 mS\/cm;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic temperature compensation:\u003c\/strong\u003e compensates for temperature between 0°C and 50°C;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic calibration:\u003c\/strong\u003e simple 1-point calibration at EC 1.4;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e90cm probe cable:\u003c\/strong\u003e gives you plenty of reach when checking pots, trays and larger containers;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReplaceable EC electrode:\u003c\/strong\u003e replace the probe rather than the complete meter when required;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust design:\u003c\/strong\u003e IP65 meter housing with an IP67-rated electrode;\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReady to use:\u003c\/strong\u003e supplied calibrated with batteries included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Measure EC in the Substrate?\u003c\/h3\u003e\n\n\u003cp\u003eThe EC of your nutrient solution tells you how strong your feed is before it reaches the roots. It doesn't necessarily tell you what is building up inside the growing medium.\u003c\/p\u003e\n\n\u003cp\u003eAs plants feed and water evaporates, dissolved mineral salts can accumulate in the substrate. Over time, the root-zone EC can end up significantly different from the solution you're putting in.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eAqua Master E300 Pro\u003c\/strong\u003e lets you check the growing medium itself, helping you identify whether nutrient levels are building up too far, dropping lower than expected or staying consistent.\u003c\/p\u003e\n\n\u003cp\u003eThis can be particularly useful with coco and other regularly fed substrates, where monitoring root-zone EC gives you another way to assess how your feeding programme is actually performing.\u003c\/p\u003e\n\n\u003ch3\u003eIdeal for Coco, Soil \u0026amp; Soft Growing Media\u003c\/h3\u003e\n\n\u003cp\u003eThe specialist EC electrode is designed to be inserted directly into \u003cstrong\u003esoft, moist substrates\u003c\/strong\u003e including coco coir, compost, potting mixes and similar growing media.\u003c\/p\u003e\n\n\u003cp\u003eThe substrate needs to be properly moist for a reliable reading. Avoid forcing the probe into dry, compacted or stony media, as poor contact can affect the measurement and may damage the electrode.\u003c\/p\u003e\n\n\u003cp\u003eThe E300 Pro can also be placed directly into nutrient solutions, making it useful as both a substrate EC meter and a conventional liquid EC meter.\u003c\/p\u003e\n\n\u003ch3\u003eCheck Root-Zone Temperature at the Same Time\u003c\/h3\u003e\n\n\u003cp\u003eThe E300 Pro measures \u003cstrong\u003etemperature alongside EC\u003c\/strong\u003e, giving you a clearer picture of conditions around the roots.\u003c\/p\u003e\n\n\u003cp\u003eRoot-zone temperature affects plant activity and nutrient uptake, so having both measurements available from the same probe makes it easier to identify whether a problem is related to nutrient strength, temperature or a combination of the two.\u003c\/p\u003e\n\n\u003ch3\u003eReplaceable EC Electrode\u003c\/h3\u003e\n\n\u003cp\u003eThe E300 Pro uses a separate substrate EC electrode connected to the meter by a \u003cstrong\u003e90cm cable\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eIf the electrode eventually becomes worn or damaged, it can be replaced without replacing the complete meter. This helps extend the useful life of the E300 Pro and makes it a practical option for growers who take regular substrate readings.\u003c\/p\u003e\n\n\u003ch3\u003eHow to Use the Aqua Master E300 Pro\u003c\/h3\u003e\n\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnect the electrode:\u003c\/strong\u003e connect the PIN connector from the EC probe to the meter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRinse the probe:\u003c\/strong\u003e rinse the electrode under clean running water and carefully dry it with clean kitchen paper.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSwitch the meter on:\u003c\/strong\u003e press the power button.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCheck the substrate is moist:\u003c\/strong\u003e the growing medium needs to be properly wet or damp for a reliable reading.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsert the electrode:\u003c\/strong\u003e gently place the probe into the soft substrate or liquid you want to measure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWait for the reading:\u003c\/strong\u003e allow the EC and temperature values to stabilise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUse the HOLD function:\u003c\/strong\u003e press HOLD if you want to freeze the measurement on screen.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClean after use:\u003c\/strong\u003e rinse the electrode thoroughly with clean water so no nutrient or substrate residue remains.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCalibration \u0026amp; Maintenance\u003c\/h3\u003e\n\n\u003cp\u003eThe Aqua Master E300 Pro uses \u003cstrong\u003e1-point automatic EC calibration at EC 1.4\u003c\/strong\u003e, making routine calibration quick and straightforward.\u003c\/p\u003e\n\n\u003cp\u003eFor consistent results, calibrate the meter regularly using fresh EC calibration solution and always rinse the electrode after testing nutrient solutions or growing media.\u003c\/p\u003e\n\n\u003cp\u003eKeeping the probe clean is particularly important when measuring directly in substrates, where particles and fertiliser residue can remain on the electrode after use.\u003c\/p\u003e\n\n\u003ch3\u003eTech Specs\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEC and temperature\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuitable for\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSoft, moist substrates and liquids\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEC range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0–19.9 mS\/cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEC resolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.1 mS\/cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEC accuracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e±2% F.S. (0.0–4.0 mS\/cm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0°C–50°C \/ 32°F–122°F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature resolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.1°C \/ 1.0°F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature accuracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e±0.5°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic, 0°C–50°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic 1-point, EC 1.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe cable length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eReplaceable substrate EC electrode\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeter protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrode protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 x 1.5V AG-13 button cell batteries\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAuto power-off\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAfter 8 minutes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 x 40 x 40mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e171g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat's Included?\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e1 x Aqua Master Substrate EC\/Temp E300 Pro meter;\u003c\/li\u003e\n  \u003cli\u003e1 x Substrate EC\/temperature electrode with 90cm cable;\u003c\/li\u003e\n  \u003cli\u003e3 x AG-13 batteries;\u003c\/li\u003e\n  \u003cli\u003e1 x User manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eTop Tip:\u003c\/strong\u003e substrate moisture has a big effect on EC readings. For useful comparisons, take your measurements at a similar moisture level and in a similar part of the root zone each time. Tracking the trend is often more useful than reacting to one isolated measurement.\u003c\/p\u003e","brand":"AQUA MASTER","offers":[{"title":"Default Title","offer_id":57577096020346,"sku":"126403","price":148.99,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/6368\/6447\/files\/AquaMasterSubstrateEC_TempE300Pro.jpg?v=1794924150","url":"https:\/\/www.onestopgrowshop.co.uk\/products\/aqua-master-substrate-ec-temp-e300-pro","provider":"One Stop Grow Shop","version":"1.0","type":"link"}