Isomax (Air Force 2) & Rhino Pro Filter Extraction Kit
  • 1 6inch kit 1  air force 2 isomax   6inch 150mm 310 360 410 m3 hr   rhino pro filter extraction kit
  • Air force 2 isomax   8 inch
  • Air force 2 isomax   12 inch
  • 90667 rhino pro filter 250mm x 600mm 1420m side view
  • Air force 2 isomax   parts
  • 1 6inch kit 1  air force 2 isomax   6inch 150mm 310 360 410 m3 hr   rhino pro filter extraction kit
  • 1 8inch kit 1  air force 2 isomax   8inch 200mm 900 m3 hr   rhino pro filter extraction kit
  • 3  air force 2 isomax fan   10inch 250mm   1500 m3 hr   rhino pro filter extraction kit
  • 3  air force 2 isomax fan   10inch 250mm   1500 m3 hr   rhino pro filter extraction kit
  • 5 air force 2 isomax fan   12inch 315mm  3300 m3%ef%80%a2hr   rhino pro filter extraction kit
  • 5 air force 2 isomax fan   12inch 315mm  3300 m3%ef%80%a2hr   rhino pro filter extraction kit

Isomax (Air Force 2) & Rhino Pro Filter Extraction Kit

SKU:

Choose your size:

6" (150mm) 310/360/410 m3/hr

£374.95 £374.95
Isomax (Air Force 2) & Rhino Pro Filter Extraction Kit
  • 1 6inch kit 1  air force 2 isomax   6inch 150mm 310 360 410 m3 hr   rhino pro filter extraction kit
  • Air force 2 isomax   8 inch
  • Air force 2 isomax   12 inch
  • 90667 rhino pro filter 250mm x 600mm 1420m side view
  • Air force 2 isomax   parts
  • 1 6inch kit 1  air force 2 isomax   6inch 150mm 310 360 410 m3 hr   rhino pro filter extraction kit
  • 1 8inch kit 1  air force 2 isomax   8inch 200mm 900 m3 hr   rhino pro filter extraction kit
  • 3  air force 2 isomax fan   10inch 250mm   1500 m3 hr   rhino pro filter extraction kit
  • 3  air force 2 isomax fan   10inch 250mm   1500 m3 hr   rhino pro filter extraction kit
  • 5 air force 2 isomax fan   12inch 315mm  3300 m3%ef%80%a2hr   rhino pro filter extraction kit
  • 5 air force 2 isomax fan   12inch 315mm  3300 m3%ef%80%a2hr   rhino pro filter extraction kit

Isomax (Air Force 2) & Rhino Pro Filter Extraction Kit

This kit provides you with everything required to create a full, odour-eliminating extraction system for your grow area, straight out of the box.

  • Buy any duct fan or extraction kit and get £40 off the G.A.S Enviro Controller!
  • Isomax (Air Force 2) duct fans – prestige products at the pinnacle of the market
  • Rhino Pro Carbon Filters – the most reliable, high-quality filters available
  • Saves you money – cheaper than buying items individually
  • All parts pre-matched for your convenience
  • Acoustic Ducting included to properly complement the silencing technology of Isomax Fans

The Isomax (Air Force 2) & Rhino Pro Filter Extraction Kit contains:

1 x Isomax (Air Force 2) Acoustic Silencer Fan
1 x Rhino Pro
1 x 5m of Acoustic Ducting
1 x Fast Clamp
1 x Duct Clip
1 x 3-Pin Fused Plug

Which size kit do I need for my Grow Tent?

There exists a (relatively) easy formula to work out which size extraction you need for your space, find out the volume in m3 (meters cubed) of your grow space with Width x Length x Height = Volume. then, Volume x 60 = Air Movement Per Hour (this will refresh the air in your grow room every minute).

If you are using a filter (which you are), Air Movement Per Hour x 1.2 = the amount of air your fan will need to move - use the figures below to match up your space to an RVK kit!

Bear in mind it's always better to over spec your fan and reduce its output with a controller, this gives you the flexibility to increase it's output to maintain optimum conditions for your plants, for example in the middle of summer.

6" (150mm) 410 m3/hr with 150mm/600mm Rhino Pro filter
8" (200mm) 570/770/870 m3/hr with 200mm/600mm Rhino Pro filter
10" (250mm) - 1480 m3/hr with 250mm/600mm Rhino Pro filter
10" (250mm) 2310 m3/hr with 250mm/1000mm Rhino Pro filter
12" (315mm) 2380 m3/hr with 315mm/600mm Rhino Pro filter
12" (315mm) - 3260 m3/hr with 315mm/1200mm Rhino Pro filter

You can purchase the seperate Isomax fans here:

Air Force 2 Isomax 

How the Isomax (Air Force 2) & Rhino Pro Filter Extraction Kit works:

Our Isomax Extraction Kits contains all of the components required to create an extraction system that will effectively treat odours and remove stale, CO2 depleted air from your grow area. We only ever include high-quality parts in our kits – no cheap rubbish. Rhino Pro Filters are easily the most reliable and effective carbon filters on the market today, and will make light work of removing unwanted smells from your grow area. All parts in the kit are also pre-matched, fitting together perfectly, straight out of the box. A fast clamp is included for connecting the Air Force 2 Fan and the Rhino Filter – for optimal performance, your Isomax Fan and Rhino Filter should always be joined together directly, and fast clamps are the simplest, most secure way to do this. The supplied ducting can then be connected to the outlet side of your Isomax Fan using the duct clip. The Isomax is one of the quietest fans on the market, so, as the perfect accompaniment, this kit includes Acoustic Ducting, which has a thick layer of insulation, reducing noise, and making it the only sensible option in an Isomax (Air Force 2) / Rhino set-up.

Using the Isomax (Air Force 2) & Rhino Pro Filter Extraction Kit:

Before connecting to a power supply, join the Isomax Fan and Carbon Filter together using the fast clamp, ensuring that the fan is placed so that, when powered-up, it will be drawing air through the filter. There are hanging attachments on either side of the Isomax to help position the fan and filter easily. Rope Ratchets make a great additional purchase: they’re perfect for supporting larger items, and, hanging fans in this way helps to lower vibration and reduce noise. Bungee cords are another tried-and-tested way to support your fan and filter and achieve similar results. Always position the fan and filter high-up in your grow space, in order to remove hot air as it rises, helping to control your grow area’s temperature. Place one end of the Acoustic Ducting onto the outlet side of the Isomax Fan and secure it into place using the duct clip. The ducting should then be placed so that it runs to a suitable outlet point, preferably to an outside area.

Keep the layout of your Acoustic Ducting simple, forming the shortest, straightest route to an outside area possible. Following this advice will lower air-resistance and allow you to get as close to 100% efficiency as is achievable. Ducting arrangements that are too long or have too many bends will create unnecessary noise and lower the effectiveness of your extraction. Putting a little time and effort into planning this aspect of your grow will pay dividends, helping to keep the air that your plants depend on as fresh as possible.

The Isomax (Air Force 2) is supplied with a pre-attached power cable of at least 1 metre in length, but will require the fitting of your 3-pin plug. The relatively short span of the supplied cable could be an issue if your fan is to be positioned in an area without a power socket in close proximity, so it may be advisable to have an electrically competent person fit it with an IEC connector (not supplied). This would allow you to power-up the unit with any cable that has an IEC connection and a suitably fused plug.

The high-torque motors on these duct fans are incredibly powerful, so under no circumstance should you ever put your fingers anywhere near the fan blades when they are operational. Doing so will almost certainly result in serious injury.